DC blinds with Encoder

Configure DC-powered blinds, slides, and awnings with encoder-based position feedback, including calibration parameters and current limits.

Position of DC blinds.

Service settings of blinds

Normal operation current

All calibration parameters are the same as for AC blinds, except for one extra parameter:

Normal operation currentDefault value
Set reverse motor directionOff

Encoder settings

Calculation of position and angle of blinds is based on counting impulses from encoder.

Encoder settings section consists of following attributes:

AttributeDefault value
Max time to wait for encoder signals start in up direction150 ms
Max time to wait for encoder signals start in down direction150 ms
Number of impulses total2000
Number of impulses for angle change
Not applicable for slides.
103
Calibration current
Limit of current during calibration.
71%
Normal operation current up
Limit of current during normal operation up.
83%
Normal operation current down
Limit of current during normal operation down.
38%
Maximal current down change
Prevent reloading blind up in case when it is moving down. Stops blind moving down in case the current down is higher than average current down in defined percent.
250%
Impulses per second to regulate speed.
Holds constant speed by using the number of impulses per second. If this is not possible to reach it holds higher possible or lower possible speed. To disable speed control set to 0.
0
Minimal PWM value.
Set minimal PWM value to regulate blind speed or to use soft start and soft end.
50